ENTOURAGE
fondpageN
email
LOGOCHR2
banblancht1a1a1a1a1
Home
Home
France
France
BNav

BEM 2 specifications

Max Intensity 400A with AC & DC

KSB6
KSB01W1

According to technological upgrades physical and electrical specifications are able to be modified .

PHYSICAL SPECIFICATIONS:
Heigth: 2200mm Width: 800mm Depth: 1200mm Weight: 1500kg PROTECTION:
with fuses, with electronic control, with temperature switch.
ELECTRICAL SPECIFICATIONS:
1) 3 modes of three-phased AC output :
- Tension generator mode from 0 to 660V with voltage regulation de tension and switched on 230V & 400V
- Current generator mode from 0 to 400A with intensity regulation.
- Asynchronous starter mode with variable ramps allowing to start at the rated current.
- Voltage & current display on digital voltmeters & ammeters.(Accuracy ± 1%) Outputs are fitted with locking safety sockets.
2) Single-phased AC 32 A with display on digital ammeter.
Output on 50 A plugs
3) Continuous power output (induced)
- Variable voltage from 0 to 900V with regulation.
- Variable intensity from 0 to 400A with regulation.( Protected against short-circuits and overheating ).
- Voltage & currant display on digital voltmeter & ammeter.
Outputs are fitted with locking safety sockets.
4) Continuous small power output (induced)
- Variable voltage from 0 to 540V with regulation.
- Max intensity 20A.
- Voltage & current display on digital voltmeters & ammeters.
Outputs are fited with locking safety sockets.
DC power supply safety switching off in case of exciting current decrease.
5) AC outputs 12V-24V-48V-115V-230V 5A DC outputs 12V-24V-48V-115V-230V 5A
6) Digital revolution counter 100 -10000 RPM with optical captor Accuracy ±1%
7) Input and digital tachometer display for dynamos control.
8) Printer plug for direct printing of voltages, intensities, cosinus ø, phases power, testing power, etc...
OPTIONAL: - "GESPROD" software provides the management of motor tests with customers's databases and test ledgers.
Display and visualization on LCD screen and double DIRIS (Voltages, Currents, Phases power)